Get reliable surge protection with our LY30-Z Lightning Rod Surge Protection Device. As a factory, we offer durable and high-quality protection for your electrical systems.
Advantages: Non-electronic type, long life. The quality of protection will not change after lightning strikes. Model with different protection radius for selection. Fully active triggered lightning system. When there is lightning, self-activation will be acted. Elegant appearance. No need maintenance. LY30Z series of pre-discharge lightning rod uses high-quality steel materials; each model has different characteristics corresponding to different protection range.Pet rochemical warehouse,gasoline st at ion, archit ect ure building, beacon station,communication base station, meteorological station, military base, radar machine room, bank building, etc.
Cat
Protectionheight Cat. l D-20M
Protectionradius (m)
Protectionheight Cat. ll D-50M
Protectionradius (m)
Protectionheight Cat. lll D-60M
Protectionradius (m)
Height of the tip of LY-30-Z-300 lightning rod to the ground Contrast list of protection radius (m)
5
42
42
57
5
64
6
42
42
58
8
67
7
43
43
59
10
68
8
43
43
60
15
72
10
43
43
63
20
75
15
44
44
65
45
83
20
45
45
70
60
85
Note: The above data is the test result when the height of the lightning rod H = 5 meters. Calculation method of the protection radius of the active pre-discharge lightning rod Suppose that the forestall start time of the lightning rod is T, then the forestall distance of upward leader △ L=V=V* △ T according to the calculation method provided by NFC-17-102 standard, the protection radius Rp is calculated according to the following formula: Representative= h(2D-h)+ △ L(2d+ △ L)h≥5 D motor distance, it depends on the level of protected buildings, for level lll protection object,D values are 20m, 45m,60m separately. h is the distance from the top of the lightning rod to the protected plane. △ T is tested by the evaluation and calculated (see table above) V=106m/s, △ L=V* △ T ■Maintechnicalparameters
lnstallation height of LY30-Z lightning rod
5
6
7
8
10
15
20
45
60
LY30-Z protection Cat. l
LY30-Z-3.1 lightning rod
22
22
23
23
25
25
25
-
-
LY30-Z-3.3 lightning rod
42
42
43
43
43
44
45
-
-
LY30-Z-4.3 lightning rod
51
51
52
52
53
53
54
-
-
LY30-Z-5.3 lightning rod
61
61
61
61
62
62
63
-
-
LY30-Z-6.3 lightning rod
70
70
70
70
71
71
72
-
-
LY30-Z protection Cat. ll
LY30-Z-3.1 lightning rod
44
44
46
47
48
51
59
-
-
LY30-Z-3.3 lightning rod
57
58
59
60
63
65
70
-
-
LY30-Z-4.3 lightning rod
68
69
69
70
73
74
79
-
-
LY30-Z-5.3 lightning rod
78
79
79
80
82
84
88
-
-
LY30-Z-6.3 lightning rod
88
89
89
90
92
93
97
-
-
LY30-Z protection Cat. lll
LY30-Z-3.1 lightning rod
50
50
52
52
55
59
74
-
-
LY30-Z-3.3 lightning rod
64
67
68
72
75
83
85
-
-
LY30-Z-4.3 lightning rod
76
78
79
82
85
92
94
-
-
LY30-Z-5.3 lightning rod
87
88
90
92
94
101
103
-
-
LY30-Z-6.3 lightning rod
97
99
100
102
104
110
112
-
-
1.Central collection rod 2.Reflector 3.Trigger device 4.Actuator 5.Fixed plate for actuatorThere is a round hole on the reflector corresponding to each actuator, and the reflector is electrically connected to the central collection rod and the ground, and the base of actuator is made of synthetic resin and it is suitable for any corrosive environment.installaton of LY30-Z lighting rod must stictly follow mandatory provisions in “Bbuilding Lightning Protection Design Code"(GB50057-2010) of Lightning Protection Standards of the People's Republic of China.